The motor is not running.
Lack of electrical power.
Check the electrical connections.
Check for possible damage or obstruction of the
rotating components.
Contact your authorised Sealey dealer.
The motor turns slowly when starting.
Power supply is of insufcient voltage.
Low level in source tank.
Clean and/or replace the valve.
Excessive suction pressure
Lower the pump with respect to the level of uid in
the tank or increase the bore of the tubing.
High loss of head in the delivery circuit (working
with the bypass open).
Use shorter tubing or increase the bore.
Dismantle the valve and clean or replace it.
Air entering the pump or suction tube.
Check seals and connections.
A narrowing in the suction tubing.
Use tubing suited to the pressures involved.
Check the voltage at the pump. Adjust voltage and/
or use cables of greater cross section.
The suction tubing is resting at the bottom of
the tank.
Irregular functioning of the bypass.
Dispense fuel until the air is purged from the
bypass system.
Air present in the diesel fuel.
Verify the suction connections.
Leakage from the body pump.
Check and replace the seal.