28) Actuate the pedal gently to raise the pressure to 20-24 bar and
keep it for 5s.
29) Follow onscreen instructions to complete operation of current
phase:
- The fill level of wheel brake circuit HZ1 (primary brake circuit)
is in order.
- Release brake pedal.
- Brake system fill status is OK.
30) Press Y button or gently actuate and then release the pedal to
complete the air inspection service and following screen shows:
........ Inspect Brake Air .... .
1. The test is OK.
2. No air is in brake
system.
3. End of test.
If the device fails to inspect brake air, following screens
come up:
prompt screen to be continued…
........ Inspect Brake Air .... .
1. Fail to inspect
brake system for
air.
2. Function of SBC is
not assured.
........ Inspect Brake Air .... .
3. Please repeat the
process.
31) Press any key to return.
VS8622_1.03_12/03/09
32